Htp MC120 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Chaudière à eau Htp MC120. HTP MC120 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 79
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
120 Braley Rd. P.O. Box 429 East Freetown, MA 02717-0429 www.htproducts.com
LP-171 Rev. 4.10.14
MC Series Gas-Fired
Circulating Heater
INSTALLATION
START-UP
MAINTENANCE
PARTS
Models
MC50 / MC80
MC99 / MC120
When installing models manufactured after July 7, 2008, you will notice additional selections on the control installer menu that will not
apply to this unit. DO NOT CHANGE THESE FACTORY SETTINGS. Refer to the Control Program Reference Chart within this manual
for selections that apply to this model.
This manual must be used by a qualified installer/service technician. Read all instructions in this manual before installing. Perform steps
in the given order. Failure to comply could result in substantial property damage, severe personal injury, or death.
NOTICE: HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors
in literature.
NOTE TO CONSUMER: PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE.
Vue de la page 0
1 2 3 4 5 6 ... 78 79

Résumé du contenu

Page 1 - Circulating Heater

120 Braley Rd. P.O. Box 429 East Freetown, MA 02717-0429 www.htproducts

Page 2 - WHAT TO DO IF YOU SMELL GAS

10 LP-171 Rev. 4.10.14 C. OPTIONAL EQUIPMENT Below is a li

Page 3 - FOR THE INSTALLER

11 LP-171 Rev. 4.10.14 Failure to keep heater area clear

Page 4 - TABLE OF CONTENTS

12 LP-171 Rev. 4.10.14 C. CLEARANCES FOR SERVICE ACCESS Se

Page 5

13 LP-171 Rev. 4.10.14 E. EXHAUST VENT AND INTAKE PIPE Ve

Page 6 - A. PRECAUTIONS

14 LP-171 Rev. 4.10.14 2. Visually inspect the venting sys

Page 7 - F. WATER CHEMISTRY*

15 LP-171 Rev. 4.10.14 The building frame (studs) must be

Page 8 - PART 2 – BEFORE YOU START

16 LP-171 Rev. 4.10.14 5. New plumbing typically has cont

Page 9

17 LP-171 Rev. 4.10.14 C. SEPARATE LOW WATER CUTOFF A low

Page 10 - C. OPTIONAL EQUIPMENT

18 LP-171 Rev. 4.10.14 SIZING SPACE HEAT SYSTEM PIPING 1.

Page 11 - B. LEVELING

19 LP-171 Rev. 4.10.14 The chart below represents various

Page 12

2 LP-171 Rev. 4.10.14 IF THE INFORMATION IN THIS MANUAL

Page 13

20 LP-171 Rev. 4.10.14 L. FILL AND PURGE HEATING SYSTEM 

Page 14 - PART 4 – PREPARE HEATER

21 LP-171 Rev. 4.10.14 M. PIPING DETAILS Figure 5

Page 15 - PART 5 – HEATER PIPING

22 LP-171 Rev. 4.10.14 Figure 6 NOTES: 1. This drawing is

Page 16 - B. RELIEF VALVE

23 LP-171 Rev. 4.10.14 Figure 7 NOTES: 1. This drawing is

Page 17 - D. BACKFLOW PREVENTER

24 LP-171 Rev. 4.10.14 Figure 8 NOTES: 1. This drawing is

Page 18 - H. CIRCULATOR SIZING

25 LP-171 Rev. 4.10.14 Figure 9 NOTES: 1. This drawing is

Page 19 - K. MULTIPLE HEATERS

26 LP-171 Rev. 4.10.14 Figure 10 NOTES: 1. This drawing i

Page 20

27 LP-171 Rev. 4.10.14 Figure 11 NOTES: 1. This drawing i

Page 21 - M. PIPING DETAILS

28 LP-171 Rev. 4.10.14 PART 6 – PIPING WITH OPTIONAL VISIO

Page 22 - Figure 6

29 LP-171 Rev. 4.10.14 D. PIPING DETAILS WITH THE VISION 1

Page 23

3 LP-171 Rev. 4.10.14 The following defined terms are us

Page 24

30 LP-171 Rev. 4.10.14 Figure 13 NOTES: 1. This drawing i

Page 25

31 LP-171 Rev. 4.10.14 Figure 14 NOTES: 1. This drawing i

Page 26

32 LP-171 Rev. 4.10.14 Figure 15 NOTES: 1. This drawing i

Page 27

33 LP-171 Rev. 4.10.14 Figure 16 NOTES: 1. This drawing i

Page 28 - A. VISION 1 SYSTEM PIPING

34 LP-171 Rev. 4.10.14 Figure 17 NOTES: 1. This drawing i

Page 29

35 LP-171 Rev. 4.10.14 Figure 18 NOTES: 1. This drawing i

Page 30

36 LP-171 Rev. 4.10.14 Figure 19 – NOTES: 1. This drawing

Page 31

37 LP-171 Rev. 4.10.14 Figure 20 NOTES: 1. This drawing i

Page 32

38 LP-171 Rev. 4.10.14 Figure 21 NOTES: 1. This drawing i

Page 33

39 LP-171 Rev. 4.10.14 PART 7 – VENTING, COMBUSTION AIR, A

Page 34

4 LP-171 Rev. 4.10.14 The latest version of the National

Page 35

40 LP-171 Rev. 4.10.14  The exhaust and intake compone

Page 36

41 LP-171 Rev. 4.10.14 D. EXHAUST VENT AND INTAKE PIPE LOC

Page 37

42 LP-171 Rev. 4.10.14 The building owner is responsible

Page 38

43 LP-171 Rev. 4.10.14 Figure 23 – LP-171-R NOTES: 1. Con

Page 39 - A. GENERAL

44 LP-171 Rev. 4.10.14 Figure 24 – Piping Exhaust around

Page 40

45 LP-171 Rev. 4.10.14 2. Inspect the area where the whit

Page 41

46 LP-171 Rev. 4.10.14 H. EXHAUST VENT AND INTAKE PIPE INS

Page 42

47 LP-171 Rev. 4.10.14 I. DIAGRAMS FOR SIDEWALL VENTING F

Page 43

48 LP-171 Rev. 4.10.14 J. DIAGRAMS FOR VERTICAL VENTING F

Page 44 - E. ROTATING THE FLUE ADAPTER

49 LP-171 Rev. 4.10.14 *NOTE: Installer must supply trap

Page 45 - G. LONGER VENT RUNS

5 LP-171 Rev. 4.10.14 F. CIRCULATORS...

Page 46

50 LP-171 Rev. 4.10.14 connection to the swirl plate and b

Page 47 - Figure 25 – Venting

51 LP-171 Rev. 4.10.14 The gas piping must be sized for th

Page 48 - PART 8 – GAS PIPING

52 LP-171 Rev. 4.10.14 Strain on the gas valve and fittin

Page 49

53 LP-171 Rev. 4.10.14 Figure 29

Page 50 - C. CHECK INLET GAS PRESSURE

54 LP-171 Rev. 4.10.14 Figure 30 – NOTE: A resistor is p

Page 51 - D. GAS VALVE

55 LP-171 Rev. 4.10.14 Figure 31 – MC Series Internal Con

Page 52 - PART 9 – FIELD WIRING

56 LP-171 Rev. 4.10.14 Connected in the heater junction b

Page 53

57 LP-171 Rev. 4.10.14 Connection Specification – Wire 18

Page 54

58 LP-171 Rev. 4.10.14 B. FREEZE PROTECTION (WHEN USED) N

Page 55

59 LP-171 Rev. 4.10.14 1. Take the 5/16" flexible cle

Page 56

6 LP-171 Rev. 4.10.14 F. CHECK FOR GAS LEAKS ...

Page 57

60 LP-171 Rev. 4.10.14 Never open the manual air vent whi

Page 58

61 LP-171 Rev. 4.10.14 3. Fill condensate trap with water

Page 59

62 LP-171 Rev. 4.10.14 To adjust, press either {S1} (Decr

Page 60 - H. CONDENSATE REMOVAL

63 LP-171 Rev. 4.10.14 water heater is satisfied, the Visi

Page 61 - PART 12 – START-UP PROCEDURE

64 LP-171 Rev. 4.10.14 18 1 Step Modulation – Regulates

Page 62 - D. TEST MODE

65 LP-171 Rev. 4.10.14 PART 14 – TROUBLESHOOTING A. ERROR

Page 63 - B. VISION 1 PROGRAM ACCESS

66 LP-171 Rev. 4.10.14 Table 14 926 Control Board FAULT C

Page 64

67 LP-171 Rev. 4.10.14 F09 No flame detected – The heater

Page 65 - PART 14 – TROUBLESHOOTING

68 LP-171 Rev. 4.10.14 heater. Installer must also inform

Page 66 - Table 14

69 LP-171 Rev. 4.10.14 2. Using a spray bottle filled with

Page 67 - PART 15 – MAINTENANCE

7 LP-171 Rev. 4.10.14 DO NOT USE THIS HEATER IF ANY PART

Page 68

70 LP-171 Rev. 4.10.14 o Visually inspect the primary pre

Page 69

71 LP-171 Rev. 4.10.14 Figure 33

Page 70

72 LP-171 Rev. 4.10.14 Figure 34

Page 71 - Figure 33

73 LP-171 Rev. 4.10.14 Figure 35

Page 72 - Figure 34

74 LP-171 Rev. 4.10.14 HEATER START-UP REPORT LIGHT OFF AC

Page 73 - Figure 35

75 LP-171 Rev. 4.10.14 INSPECTION ACTIVITIES DATE LAST CO

Page 74 - MAINTENANCE REPORT

76 LP-171 Rev. 4.10.14

Page 75

77 LP-171 Rev. 4.10.14

Page 76

78 LP-171 Rev. 4.10.14 MAINTENANCE NOTES

Page 77

79 LP-171 Rev. 4.10.14 HTP CUSTOMER INSTALLATION RECORD

Page 78

8 LP-171 Rev. 4.10.14  Water pH between 6.0 and 8.0 o M

Page 79

9 LP-171 Rev. 4.10.14 Modulating Combustion System Modula

Modèles reliés MC99 | MC80 | MC50 |

Commentaires sur ces manuels

Pas de commentaire